THE K2U POLAR NOMOGRAM: AN INTERACTIVE VISUALIZATION METHOD FOR REAL-TIME ASSESSMENT AND SOURCE DIAGNOSIS OF THREE-PHASE VOLTAGE UNBALANCE

Main Article Content

Javokhir Sherbaev
Akmal Abdumalikov

Abstract

Continuous monitoring of the voltage unbalance factor K2U produces long streams of numbers that answer the regulatory question — is the 2 % normal or 4 % maximum limit of GOST 32144-2013 exceeded? — only after inspection of tables or time-series plots, and say nothing direct about where the unbalance comes from. We describe a polar nomogram in which the radial coordinate is K2U, the angular coordinate is the phase angle φ2 of the negative-sequence voltage component, and the normative limits appear as concentric zone boundaries. A single glance then answers both questions at once: the distance of the operating point from the centre shows the margin to the limits, and the angular sector in which measurements cluster points to the origin of the unbalance. The method is implemented as an interactive web module with live recomputation, a history trail and a drag-to-explore inverse mode, and is illustrated on a simulated telecommunications load profile in which the φ2 cluster correctly identifies the loaded phase.

Downloads

Download data is not yet available.

Article Details

Section

Articles

How to Cite

Sherbaev, J., & Abdumalikov, A. (2026). THE K2U POLAR NOMOGRAM: AN INTERACTIVE VISUALIZATION METHOD FOR REAL-TIME ASSESSMENT AND SOURCE DIAGNOSIS OF THREE-PHASE VOLTAGE UNBALANCE. Konferensiyalar, 1(1), 8-12. https://doi.org/10.5281/zenodo.23137085

References

Pillay P., Manyage M. Definitions of voltage unbalance // IEEE Power Engineering Review. — 2001. — Vol. 21, No. 5. — P. 50–51.

Gnacinski P. Windings temperature and loss of life of an induction machine under voltage unbalance combined with over- or undervoltages // IEEE Transactions on Energy Conversion. — 2008. — Vol. 23, No. 2. — P. 363–371.

GOST 32144-2013. Electric energy. Electromagnetic compatibility of technical equipment. Power quality limits in public power supply systems. — M.: Standartinform, 2014.

GOST 30804.4.30-2013 (IEC 61000-4-30). Electric energy. Methods of measurement of power quality indices. — M.: Standartinform, 2014.

Fortescue C.L. Method of symmetrical co-ordinates applied to the solution of polyphase networks // Transactions of the AIEE. — 1918. — Vol. 37, No. 2. — P. 1027–1140.

Bostock M., Ogievetsky V., Heer J. D3: Data-Driven Documents // IEEE Transactions on Visualization and Computer Graphics. — 2011. — Vol. 17, No. 12. — P. 2301–2309.

Wang Y.J. Analysis of effects of three-phase voltage unbalance on induction motors with emphasis on the angle of the complex voltage unbalance factor // IEEE Transactions on Energy Conversion. — 2001. — Vol. 16, No. 3. — P. 270–275.

Ferreira Filho A.L., Cormane J.A.A., Garcia D.C., Costa M.V.C., Oliveira M.A.G., Nascimento F.A. Analysis of the complex voltage unbalance factor behavior resulting from the variation of voltage magnitudes and angles // Proceedings of the 14th International Conference on Harmonics and Quality of Power (ICHQP). — Bergamo, 2010. — P. 1–7.